EasyManua.ls Logo

Bosch CR 10 - Fault Code Analysis

Bosch CR 10
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Eliminating faults | 11
6720830560 (2015/06)
CR10
Table 3 Fault code and sub-code for the contractor
For further information, see the service manual if necessary
fault code
sub-code
Possible cause and
assistance from the contractor
A61
...
A68
3091 ...
3098
Room temperature sensor of the CR 10 defective (A61/
3091: Heating circuit 1, ..., A68/3098: Heating circuit 8).
Replace the CR 10.
A21 1001 CR 10 in Heating circuit 1 incorrectly configured.
If a higher-level user interface (e.g. CW 400) is installed,
set A.1 = Fb (remote control).
If a zone module is installed and recognized, set A.1 = SC
(zone controller).
If no higher-level user interface and only one heating circuit
is installed, set A.1 = CO (controller).
A22
...
A28
1001 BUS signal from the higher-level user interface for remote
heating is missing (A22: Heating circuit 2, ..., A28: Heating
circuit 8).
Install the higher-level user interface (e.g. CW 400).
Establish the BUS connection.
A61
...
A68
1081
...
1088
CR 10 incorrectly configured (A61/1081: Heating circuit 1, ...,
A68/1088: Heating circuit 8).
Set A.1 = Fb (remote control).
A61
...
A68
3061
...
3068
CR 10 incorrectly configured (A61/3061: Heating circuit 1, ...,
A68/3068: Heating circuit 8).
For assistance, see Fault code A21.
Fill - Water pressure in the heating system is too low.
Top up the heating water (even without a contractor,
Æ technical documentation about the heat source).

Related product manuals