6 720 820 871 (2016/12)CR 400 | CW 400 | CW 800
Working with the main menu | 19
5.2 Heat source settings
This menu is only available for certain types of heat source if the
system is designed and configured accordingly (e.g. in systems
without cascade module).
Menu: Heat appliance
5.3 Adapting settings for heating system
automatic mode
Normally, the time program provides the best heating comfort.
In the default settings for each heating circuit, time program 1
is active with the following settings:
• Starting at 06:00 (08:00 on Saturdays and Sundays) heat
to 21 °C (heating mode). Starting at 23:00 heat to 15 °C
(setback mode).
These settings provide economic heating from 23:00 in the
evening until 06:00 in the morning on the following day.
Heating circuit 1 ... 4 with C 400 or heating circuit 1 ... 8
with C 800
If more than one heating circuit has been installed and
configured, the settings for heating circuits 1 ... 4 or 8 are
changed in the same way as for systems with one heating
circuit. However, changes are valid only for the selected
heating circuit.
A remote control can be installed for each heating circuit. If an
CR100 is assigned to a heating circuit as a remote control, the
CR100 determines the time program for the heating system.
For this heating circuit, the time program cannot be set at the C
400/C 800. The Time program menu is not displayed for the
heating circuit assigned to the remote control. The most recent
change to the operating mode in this heating circuit (on the
CR100 or the C 400/C 800) is always the valid setting.
Menu: Heating
Menu item Description
Activate
emergency
operation /
Deactivate
emergency
operation
In emergency operation, heating and
DHW heating are active.
Emerg. op. flow
temp.
Set flow temperature in emergency
operation
Heating Switch the heating system on and off.
Heating max.
temperature
Maximum flow temperature for
heating system
DHW Switch DHW heating on and off.
DHW max. temp. Maximum DHW temperature
Table 13 Heat source settings
Menu item Description
Temperature
settings/
Setback
threshold
If the time program with 2 temperature
levels is active, the temperatures for the
2 levels Heating and Setback can be set
in this menu.
If the time program with Freely
adjustable temperature is active, the
setback threshold is set here. This is the
temperature above which the setback
mode is activated.
(Æ Tab. 15, page 20)
Time program Æ Chapter 5.3.2, page 21
Start opt. time
prog.
Æ Chapter 5.3.3, page 25
Sum./wint.
changeover
Æ Chapter 5.3.4, page 25
Operating Mode Only available if the control type Constant
is set for the selected heating circuit
(Æ Chapter 5.3.1, page 21).
Table 14 Settings for heating system automatic mode