Technical information
19
Compress 3400i AWS – 6721825369 (2021/11)
later on. Charged objects are only a problem if they are in the vicinity of
the electronics. Observe a safety clearance of at least one metre from
foam rubber, protective film and other packaging materials, and do not
wear clothing made of synthetic fibres (e.g. fleece pullovers) and similar,
when you start work.
An earthed wrist strap offers good ESD protection when working with
electronics. This wrist strap must be worn when opening the screened
metallic bag/packaging or prior to exposing a fitted PCB. The wrist strap
must be worn until the PCB has been placed inside its screened
packaging or has been connected inside the closed control device.
Replaced PCBs that are returned must be handled in this way.
8.5 Pump down the refrigerant
Remove the side cover to access the valves (instructions to remove
side cover at Fig. 15).
Ensure that the system is installed correctly and ready for operation.
Connect the manifold gauge to the service valve of low pressure side
(larger diameter).
Select “tt” >> “PD” option in the ODU HMI menu.
After approximately 1 minute the message “Cls Liq” will show in the
HMI. Close the liquid service valve (smaller diameter) with a hex key.
When the message “End” is visible in the HMI, immediately close the
gas service valve with a hex key.
9 Technical information
9.1 Technical specifications of CS3400iAWS 4-10 OR-S
Unit CS3400iAWS 4 OR-S CS3400iAWS 6 OR-S CS3400iAWS 8 OR-S CS3400iAWS 10 OR-S
Operation, air/water
Max power output with A2/W35
1)
kW 3.81 5.98 7.35 7.85
COP with A2/35
1)
3.39 3.72 3.47 3.38
Max. power input A2/W35
1)
kW 1.13 1.61 2.12 2.32
Modulation range with A2/W35 kW 2.1 - 3.8 2.1 - 6.0 2.1 - 7.4 2.1 - 7.9
Max. output with A7/W35
1)
kW 5.21 6.15 8.02 9.41
COP with A7/W35 (100%) 4.68 4.75 4.70 4.43
Power output with A7/W35, nominal kW 4.42 6.15 8.02 8.92
COP with A7/W35, nominal 4.70 4.75 4.70 4.69
Max. power output with A7/W55
1)
kW 3.89 4.99 6.77 6.77
COP with A7/W55
1)
2.71 2.60 2.69 2.69
Max. power output with A-7/W35
1)
kW 4.32 5.09 6.22 6.94
COP with A-7/W35
1)
2.89 3.02 2.77 2.76
Max. power output with A-10/W35
1)
kW 3.92 4.50 5.54 6.20
COP with A-10/W35
1)
2.69 2.67 2.51 2.50
Max. power output with A-7/W55
1)
kW 3.62 5.31 5.31 5.31
COP with A-7/W55
1)
1.81 1.79 1.79 1.79
Cooling Data
Cooling capacity with A35/W7
1)
kW 3.70 4.97 5.83 6.00
EER with A35/W7
1)
3.29 3.20 3.15 3.12
Max. power input for A35/W7
1)
1.12 1.55 1.85 1.92
Cooling capacity with A35/W18
1)
5.39 6.94 8.44 9.02
EER with A35/W18
1)
4.53 4.33 4.07 3.93
Max. power input for A35/W18
1)
kW 1.19 1.60 2.07 2.30
Cooling capacity with A35/W18, nominal 4.90 6.27 6.94 7.95
EER with A35/W18, nominal - 4.74 4.65 4.33 4.25
Electr. Data
Power supply 230V ~1N
Recommended automatic circuit breaker/fuse
2)
A16 20
Maximum current A 10 16 16
Startup current A 10
Performance factor cos φ with maximum output >0.92
Information for refrigerant circuit
Connection type Flare connection 1/4” &
1/2”
Flare connection 1/4” & 5/8”
Refrigerant type
3)
R32
Refrigerant charge kg 1.1 1.3
CO
2
(e) Tonne 0.743 0.878
Air and noise data
Nominal air flow rate m
3
/h 1800 2600
Sound pressure level at a distance of 1 m dB(A) 53 51 51 51
Sound power
4)
dB(A) 61 59 59 59
Max. sound power - day dB(A) 64 61 61 62
Max. sound power - night (silent mode) dB(A) 58 56 56 57