Technical information
Compress 3400i AWS – 6721825369 (2021/11)
20
Table 9 Outdoor unit
Note that if a sound hood (accessory) is installed on the outdoor unit, the
performance will be reduced.
9.2 Operating range of the outdoor unit
Fig. 24 Operating range of heat pump in cooling mode
[T0] Flow temperature
[T1] Outdoor temperature
Fig. 25 Operating range of heat pump in heating mode without auxiliary
heater
[T0] Flow temperature
[T1] Outdoor temperature
Tonality addition - day
5)
dB 3 3 3 3
Tonality addition - night
5)
dB0000
General information
Maximum heating water flow temperature, outdoor unit
only
ºC 60
Protection class IPX4
Installation altitude Up to 2000 m above sea level
Dimensions (WxDxH) mm 976 x 380 x 609 975 x 380 x 864
Weight (without packaging) kg 50 66
Fan motor 50 80
1) At 100% compressor speed
2) No specific fuse rating or type is required. The starting current is low and will not exceed the operating current.
3) GWP
100
= 675 (R32), 2088 (R410A)
4) Sound power level in accordance with EN 12102 (nominal output with A7/W55)
5) According to DIS47315/150257, April 2004 and following requirements of TA Lärm
Unit CS3400iAWS 4 OR-S CS3400iAWS 6 OR-S CS3400iAWS 8 OR-S CS3400iAWS 10 OR-S
0
5
10
15
20
25
30
5 101520253035 455040
T0 [°C]
T1 [°C]
0010035472-001
45
50
15
20
25
30
5 10152025303540
35
40
45
50
55
60
65
0-5-10-15-25 -20
T0 [°C]
T1 [°C]
0010035494-001