D6412/D4412 Operation and Installation Guide
D6412/D4412
Page 45© 2003 Bosch Security Systems 45349E
Arming Devices
11.0 Arming Devices
11.1 Description
Command centers, maintained or momentary contact keyswitches, Premises RF arming devices, or any of these devices in
combination are used to arm and disarm areas. The D6412 may contain up to four areas (up to two areas on the D4412)
that can be armed and disarmed individually.
11.2 Command Centers
A Bosch Security Systems command center is a four-wire SDI device used to arm and disarm areas, annunciate complete
system status, initiate system tests, and control many functions of the security system.
The panel can supervise up to eight wired command centers and 4 RF Keypads. The panel transmits a Serial Device Trouble
Report, SDI MISSING in the Modem IIIa
2
format or SYS PERIPHERAL TROUBLE in the CONTACT ID format, if it
loses communication with a wired supervised command center. RF Keypads are shown as missing by SDI address. See RF
Keypads in the D6412/D4412 Program Entry Guide (P/N: 45351).
SYSTEM FAULT appears in any command center with text display capability that loses communication with the panel. A
system trouble appears at all other command centers connected to the system. SYSTEM FAULT also appears for
approximately 10 sec. during power up.
See Command Center in the D6412/D4412 Program Entry Guide (P/N: 45351) for complete programming and operation
details for command centers.
11.2.1 Assigning the Command Center an Address
On-board DIP switches are used to assign a unique address to the command center. Command centers 1 to 8 are assigned to
SDI address 1 to 8. See Command Centers in the D6412/D4412 Program Entry Guide (P/N: 45351) for a complete description
of command center programming (area assignment, etc.).
Table 14 shows the correct address setting for each command center address. See Figure 31 for proper command center DIP
switch orientation.
SDI Address Switch Number, X = Switch On
1 2 4 8 16 Mode
0* OFF OFF OFF OFF OFF OFF
1
ON
OFF OFF OFF OFF
ON
2OFF
ON
OFF OFF OFF
ON
3
ON ON
OFF OFF OFF
ON
4OFFOFF
ON
OFF OFF
ON
5
ON
OFF
ON
OFF OFF
ON
6OFF
ON ON
OFF OFF
ON
7
ON ON ON
OFF OFF
ON
8 OFF OFF OFF
ON
OFF
ON
Table 16: Command Center Address Assignments DIP Switch Settings
* Address 0 is reserved for the installer’s keypad. This keypad is not intended for permanent installation and should
remain on-premises for future programming sessions. See Section 13.0 Installer’s Keypad and Installer’s Mode, for
more information.
ON
123456
1 2 4 8 16 MODE
ADDRESS
OFF
ON
Example:
Module Address 2
Figure 31: Command Center DIP Switch Orientation