EasyManua.ls Logo

Bosch D4412 - Installers Keypad and Installer Mode; Installers Keypad Connector; Entering the Installer Mode

Bosch D4412
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D6412/D4412 Operation and Installation Guide
D6412/D4412
Page 53© 2003 Bosch Security Systems 45349E
13.0 Installer’s Keypad and Installer Mode
13.1 Installer’s Keypad Connector
The Installer’s Keypad must be set to Address 0 (set MODE to OFF) and the Installer Switch must be closed in order
to program the panel from the keypad.
Figure 43 shows you how to connect and disconnect an Installer’s Keypad (D623 or D625 Text Command Center) and enter
the Installer’s Mode. Refer to D6412/D4412 Program Entry Guide (P/N: 45351) for complete information on programming
the panel from a keypad.
Use wire assemblies supplied with keypad and panel to create a double ended “installer” cable.
D6412/D4412 PCB
Y
G
B
R
Back of Command Center
RedR
Y
G
B
Yellow
Green
Black
Connector supplied
with keypad.
Connector supplied
with panel.
Figure 43: Installer’s Keypad
13.2 Entering the Installer Mode
I
MPORTAN
T
Press the [Cmd] key when the Text Command Center display prompts you to press the [#] key.
13.2.1 Installer’s Passcode
To enter the Installer’s Mode, first enter the installer’s passcode and then press [Cmd][4][1]. The default Installer Passcode is
6543210. The passcode length can be between 3 and 7 digits in length. The default length is four digits, which shortens the
default Installer passcode to 6543. To change the default passcode length, see Section 2.9 Passcode Configuration, Installer
Passcode in the D6412/D4412 Program Entry Guide (P/N: 45351).
The system displays the Installer’s Menu described in Section 13.3 Installer’s Menu.
I
MPORTAN
T
The Installer Switch must be closed to select Keypad Program from the Installer’s Menu (see Figure 43).
Installer’s Keypad and Installer Mode

Table of Contents

Related product manuals