EasyManua.ls Logo

Bosch D7412GV3 - Installing the Control Panel; Earth Ground and Fault Detection Setup

Bosch D7412GV3
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 en | Add System Users Locally With a Keypad D9412GV3/D7412GV3/D7212GV3
F01U170805 | 01 | 2010.11 Quick Reference Guide Bosch Security Systems, Inc.
7 Add System Users Locally With a Keypad
7.1 Add Users (CMD 56) Using a Keypad
Table 7.1 Adding Users with Command 56
7.2 Add Card (CMD 56) for Access Control Only Using a Keypad
Table 7.2 Adding Cards with Command 56
Step Operator Entry Keypad Response
1 Enter Command 56 Enter Passcode
2 Enter passcode and press [ENT]. Enter User #
3 Enter the user number and press [ENT]. USER # (default name text)
4 Enter Change Passcode?
5Enter Enter New Code
6 Enter the new user’s passcode. Enter New Again
7 Re-enter the new passcode. Code Changed
Step Operator Entry Keypad Response
1 Command 56 Enter Passcode
2 Enter passcode and press [ENT] Enter User #
3 Enter the user number and press [ENT] USER# (default name text)
4 Enter Change Passcode?
5Next Add Card?
6 Enter Present Card
7 Present the credential to the reader. Card Added
NOTICE!
To use Add Card (CMD 56), you must program the Assign Door prompt within Command
Center Assignments with the D9210B door controller number. If you do not program the
Assign Door prompt, the keypad reads 9210 NOT READY.