D9412GV3/D7412GV3/D7212GV3 Upgrade GV3 Hardware and Programming | en 7
Bosch Security Systems, Inc. Quick Reference Guide F01U170805 | 01 | 2010.11
2 Upgrade GV3 Hardware and Programming
2.1 Receive Existing Control Panel Programming
2.1.1 Receive Existing Control Panel Programming with RPS
1. In RPS, double-click on the control panel name.
2. Click Connect. Once connected, the Panel Sync window opens.
3. Select the Recieve Panel Data option button and click OK.
2.2 Upgrade Hardware to a GV3 Series Control Panel
2.2.1 Prepare to Remove Existing Hardware
1. Power down the existing control panel by disconnecting the battery and the AC power.
2. Remove the four removable terminal strips by tilting the strip up and outward.
Do not remove the wiring from the terminal strip.
2.2.2 Remove the Existing Control Panel
1. Remove the lock down tab screw.
2. Lift up on the control panel to free it from the enclosure mounting hooks, and remove the
control panel from the enclosure it.
NOTICE!
GV3 Series v8.11 and later Control Panels are not compatible with the D5200 Programmer.