DINION 3100i IR Configuration | en 35
Bosch Security Systems B.V.
User manual
2024-02 | V01 | DOC
Stream
Identifies the current stream.
Zoom
Identifies the current zoom factor of the camera (1x, 2x, 4x, or 8x).
Averaging period
Identifies how often (in seconds, minutes, hours, days or weeks) the encoder time is
synchronized to the actual time.
5.4.10 Privacy Masks
Privacy Masks block specific areas of a scene from being seen in the camera's field of view.
This can be useful when public spaces are in the coverage area or monitoring will be limited
to a particular zone.
Pattern
Select the color of the mask as it will appear in the live video: Auto, Black, Gray, White or
Custom color.
When Auto is selected, for one or more masks with a similar background, these will try to
blend with the surrounding color. If the backgrounds have different colors, the masks will
average between the colors.
A total of eight (8) masks can be in view at the same time.
To configure a Privacy mask:
– Select the mask number from the drop-down list.
– Click the plus button.
– Adjust the mask in the image:
– Double-click on the edges to add or remove nodes.
– Click and drag the nodes to position them correctly.
– Check the Enabled check box to activate the related mask.
– Click the Set button to apply the related changes.
To delete a Privacy mask:
– Select the mask number from the drop-down list.
– Click the trashcan icon.
– Click the Set button to apply the changes.
5.4.11 Pixel Counter
The number of horizontal and vertical pixels covered by the highlighted area is displayed
below the picture. With these values you can check whether the requirements for specific
functions, for example, identification tasks, are fulfilled.
1. Click Freeze to freeze the camera image if the object that you want to measure is
moving.
2. To reposition a zone, place the cursor over the zone, hold down the mouse button and
drag into position.
3. To change the shape of a zone, place the cursor over the edge of the zone, hold down
the mouse button and drag the edge of the zone to the required position.
5.5 Recording
Images can be recorded to an appropriately configured iSCSI system or, for devices with a
micro SD slot, locally to a micro SD card.
SD cards are the ideal solution for shorter storage times and temporary recordings. They
can be used for local alarm recording or to improve the overall reliability of video recording.
For long-term authoritative images use an appropriately sized iSCSI system.