Page 130 P/N: 4998152533-02 Copyright 2007 Bosch Security Systems, Inc. DS7200V2-UK Installer's Guide
PART V: REFRENCE MATERIALS
Event #
Event as shown
in Panel Log
SIA Report
SIA Report Data
Contact ID Report
Event Description
Zone Types
Linked to Event
RPS
Event
Group
Status
Reports
121 RF Battery Low Transmitter
Battery
Trouble
ri {area} XT {RF device
#}
384 RF Low Battery
Low Battery detected
on premises RF
transmitter.
Any zone type 9
122 RF Battery Rstl Transmitter
Battery
Restoral
ri {area} XR {RF device
#}
384 RF Low Battery
Low Battery condition
detected on premises
RF transmitter cleared.
Any zone type 9
123 RF Tamper Flt Tamper
Trouble
ri {area} TT {RF device
#}
383 Sensor Tamper
Premises RF
Transmitter Tamper
Fault (Trouble)
Any zone type 9
124 RF Tamper Rstl Tamper
Trouble
Restore
ri {area} TR {RF device
#}
383 Sensor Tamper
Premises RF
Transmitter Tamper
Restoral
Any zone type 9
125 DBus Missing Expansion
Device
Missing
EM {SDI address} 333 Exp. Module
Failure
Data Bus device not
responding to polling.
12 R S
126 DBus Missing,Rstl Expansion
Missing
Restore
EN {SDI address} 333 Exp. Module
Failure
Data Bus device
declared as missing
now responding to
polling.
12 R S
127 DBus Tamper Expansion
Device
Tamper
ES {SDI address} 341 Exp. Module
Tamper
Tamper open on Data
Bus Device Tamper.
12 R S
128 DBus Tamper,Rstl Expansion
Tamper
Restore
EJ {SDI address} 341 Exp. Module
Tamper
Data Bus Device
Tamper Restoral.
12 R S
129 DBus Fault Expansion
Trouble
ET {SDI address} 330 System
Peripheral Trouble
Fault (Trouble)
detected on Data Bus
Device.
12 R S
130 DBus Fault ,Rstl Expansion
Restoral
ER {SDI address} 330 System
Peripheral Trouble
Data Bus Device Fault
(Trouble) condition
cleared.
12 R S
131 DBus OverCurrent Overcurrent
Trouble
pi {SDI address} YI 330 System
Peripheral Trouble
Over current condition
detected on Data Bus
device.
12 R S
132 DBus OverCur,Rstl
Overcurrent
Restore
pi {SDI address} YJ 330 System
Peripheral Trouble
Over current condition
on Data Bus device
restored.
12 R S
133 Sensor Mon Flt No Activity ri {area} NA {loop} 391 Sensor Watch
trouble
Sensor fault (trouble)
detected. Reports
follow zone fault
(trouble) routing.
11 - 15 6
134 Sensor Mon Rstl Activity
Restored
ri {area} NS {loop} 391 Sensor Watch
trouble
Sensor trouble
condition restored.
Reports follow zone
trouble routing.
11 - 15 6
135 Sensor Reset Local Event
Only
User entered System
Reset key sequence
([#] + [4] + [7]).
12
136 System Inactive Closing
Delinquent
CD {area} System was not armed
in Inactive Interval. See
Section System
Inactive Interval on
page 48
. System Reset
key sequence
([#][4][7]) or arming
resets this trouble.
12 R
137 Test, OK Automatic
Test
RP 602 Period Test
Report
No system troubles at
automatic test report
time.
13
138 Test,Off-Normal Test Off
Normal
ri {0} RY {0} 608 Period Test
Report, System
Trouble Present
System trouble present
at test time.
13
Table 47: Control Panel Events and Reporting Formats (continued)