DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 53
PART IV: CONTROL PANEL PROGRAMMING
34.0 Programming Options
Remote Programming Options
Address: 0256
Default: 5
Selections: 0, 1, 3, 5, 7
Enter This Data Digit to Select Options
Remote Programming Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
Disable Remote Programming
Enable Remote Programming
Enable Remote Programming Callback
Terminate Remote Programming Session on Alarm
Reserved
Enable Remote Programming: If this option is enabled, the system answers the call at the programmed ring count for
remote programming sessions. [#][4][3] can also be used to start a remote programming session or answer the call if
Address 0213 is set to 0. See
RPS Answer Ring Count, Answer Machine Bypass on page 46.
If the programming session is completed successfully, the control panel sends a Valid Remote Access {103} report.
If you change the control panel parameters during the programming session, it sends a Parameters Changed {98}
report.
If the programming session is terminated with a ‘reset panel’ from RPS, the control panel sends a Reboot {104} report.
If the programming session is not successfully completed, the control panel sends an Invalid Remote Access {102}
report.
Select the “Enable Remote Programming” option to ensure that the following options operate
properly.
Enable Remote Programming Callback: If this option is enabled, the system answers the call at the programmed ring
count for remote programming sessions. If it determines that the remote programmer is calling, it will disconnect and call the
remote programmer back using the programmed call-back phone number/IP address (see page 45). When this is enabled,
[#][4][3] can also be used to start a programming session. When a user presses [#][4][3] at the keypad, the control panel
calls RPS. If the callback to RPS is not successful, it sends a Bad Call {101} report..
Terminate Remote Programming Connection on Alarm: If this option is enabled, an alarm on any zone or any keypad
terminates the remote programming session.