DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 129
PART V: REFERENCE MATERIALS
Event #
Event as shown
in Panel Log
SIA Report
SIA Report Data
Contact ID Report
Event Description
Zone Types
Linked to
Event
RPS
Event
Group
Status
Reports
94 Open,RPS,Alarm Disarm from
Alarm
ri {area} OR {254} 400 Open/Close Opening after Alarm event
by RPS.
95 Open,Usr,Alarm Disarm from
Alarm
ri {area} OR {user} 401 O/C by User Opening after Alarm event,
ID reported.
10
96 Open,KS,Alarm Disarm from
Alarm
ri {area} OR {255} 409 Keyswitch O/C
Opening after Alarm event
by Keyswitch
10
97 Reserved
98 Params Changed Parameter
Changed
YG 306 Panel
Programming
Changed
Panel Parameters Changed
12 R
99 Phone Line Fail Phone Line
Trouble
LT {phone line} 351 Telco 1 fault
Phone line voltage less than
3 volts for 40 seconds.
12 R S
100 Phone Line Rstl Phone Line
Restoral
LR {phone line} 351 Telco 1 fault After Phone Line Fail event,
phone line voltage detected
at greater than 3 volts for 40
seconds.
12 R S
101 Bad Call to RPS Remote
Programmer
Call Failed
RA 413 Unsuccessful
access
Panel attempted call to
RPS, but was unsuccessful.
12 R
102 RPS Access Fail Remote
Program
Fail
RU 413 Unsuccessful
access
RPS attempted to connect
to panel but was not
successful.
R
103 RPS Access OK Valid
Remote
Access
RS 412 Successful
Download/Access
RPS successfully
connected to and
disconnected from panel.
R
104 Re-Boot,Panel Power Up RR 305 System reset Normal start up or reset by
RPS.
R S
105 Re-Boot,DBus Power Up pi {SDI address} RR 339 Exp. Module
Reset
Unexpected reset (reboot)
from Option Bus device.
12 R S
106 Output Reset,Usr Relay Open
id {user} RO {output #} 320 Sounder/Relay
Output Reset by User 16 R
107 Output Reset,Tmr Relay Open
id {252} RO {output #} 320 Sounder/Relay
Output Reset by Sked
(Timer)
16 R
108 Output Reset,
RPS
Relay Open
id {254} RO {output #} 320 Sounder/Relay
Output Reset by RPS R
109 Output Set,Usr Relay Close
id {user} RC {output #} 320 Sounder/Relay
Output Set by User 16 R
110 Output Set,Tmr Relay Close
id {252} RC {output #} 320 Sounder/Relay
Output Set by Sked (Timer) 16 R
111 Output Set,RPS Relay Close
id {254} RC {output #} 320 Sounder/Relay
Output Set by RPS R
112 Rstrl,Tamper Tamper
Restoral
ri {area} TR {loop} 137 Tamper Restoral from alarm,
Tamper zone type.
4- Tamper 8
113 Rstrl,Emergency Emergency
Restoral
ri {area} QR {loop} 101 Personal
Emergency
Restoral from alarm,
Emergency zone type.
5-
Emergency
8
114 Rstrl,Panic Panic
Restoral
ri {area} PR {loop} 120 Panic Restoral from alarm, Panic
zone type.
6- Visible
Panic
8
115 Rstrl,Invisible Holdup
Restoral
ri {area} HR {loop} 120 Panic Restoral from alarm,
Invisible zone type.
7-Invisible
Panic
8
116 Rstrl,24-hr Burg Burglary
Restoral
ri {area} BR {loop} 133 24hr (Safe) Restoral from alarm, 24-
hour burglary zone types.
8- Burglary
15- Door
8
117 Rstrl,Cntrl,Dly Burglary
Restoral
ri {area} BR {loop} 134 Entry/Exit Restoral from alarm, zone
types.
11- Delay 1
12- Delay 2
8
118 Rstrl,Cntrl Burglary
Restoral
ri {area} BR {loop} 130 Burglary Restoral from alarm, zone
types.
10-
Keyswitch
13- Follower
14- Instant
8
119 Rcvr Jam RF
Interference
XQ {RF device #} 344 RF Receiver
Jam Detect
Jammed condition detected
on premises RF receiver.
9 R S
120 Rcvr Jam Rstl RF
Interference
Restoral
XH {RF device #} 344 RF Receiver
Jam Detect
Restoral
Jammed condition detected
on premises RF receiver
cleared.
9 R S
Table 47: Control Panel Events and Reporting Formats (continued)