DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 55
PART IV: CONTROL PANEL PROGRAMMING
Arming Options 2
Address: 0259
Default: 0
Selections: 0-15
Enter This Data Digit to Select Options
Arming Options 2 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
No Options Enabled
First Area to Open/Last Area to Close Reporting
Make Area 1 Common Area
Enable All Areas All On ([#][8][0])
Enable All Areas All Off ([#][8][1])
First Area to Open {164}/Last Area to Close {165} Reporting: If this option is enabled, the system sends one Closing
{165} report when all areas are turned On and one Opening {164} report when any area is turned Off. Opening/Closing
reports must be enabled for all areas.
Enabling the “Restrict Open/Close Reports” option overrides the “First Area to Open/Last Area to
Close Reporting” option. See Area # Opening {89-96}/Closing {42-67} Reporting Options on page 61
for more information on the “Restrict Open/Close Reports” option.
All area account numbers must be the same in order to send Area 1’s account numbers. See Areas
on page 60 for account number programming instructions.
Make Area 1 Common Area: If this option is enabled, all other areas are made common to Area 1. Area 1 arms when all
the other areas are armed All On, and Area 1 disarms when any other area is disarmed.
Enable All Areas All On Function ([#][8][0]): If this option is enabled, all areas arm when a user enters [#][8][0]. Faulted
zones are force-armed. Enable all areas in which the user has the appropriate authority level.
Enable All Areas Off Function ([#][8][1])*: If this option is enabled, all areas disarm when a user enters [#][8][1]. This
function always requires a PIN. Enable all areas in which the user has the appropriate authority level.