DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 65
PART IV: CONTROL PANEL PROGRAMMING
PIN, User #
Address: See Table 26
Default:
User 1: 1, 2, 3, 4, 0, 0, 0
Users 2-32: 15, 15, 15, 15, 15, 15, 15
Selections: 0-9
Enter a PIN for each user in the PIN parameter. The PIN length parameter determines the number of digits in the PINs.
The default PIN length is 4 digits, which makes all User PINs four digits in length. For example, if a User PIN is 7654321 and
the PIN length is set to 4 digits, the User PIN changes to 7654.
Do not use digits 10-15 when creating a User PIN. Entering these digits makes the PIN unusable and
locks the user out of the control panel.
Authority Level, User #
Address: See Table 26
Default:
User 1: 1 (Authority Level 1)
User 2: 2 (Authority Level 2)
User 3: 3 (Authority Level 3)
Users 4-32: 0 (No Authority Level assigned)
Selections:
0 = No Authority Level assigned (Disabled)
1 = Authority Level 1 assigned
2 = Authority Level 2 assigned
3 = Authority Level 3 assigned
4 = Authority Level 4 assigned
This parameter assigns an authority level to each user. The authority level assigns functions to the user’s PIN and RF keyfob.
See
RF Keyfobs on page 102 for a description of RF keyfobs and how to assign them to users.
Authority levels are configured as shown below. See “Authority Level Configuration” in the
DS7200V2 Expert Programming
Guide (P/N: 4998153891) to change the configuration of authority levels.
Authority Level 1 (Master): All options except for Option 5. A user with this authority level configuration can arm and disarm
the system, send reports, and perform all system functions except one-time disarm.
Authority Level 2 (Unlimited): All options except for Option 5. A user with this authority level configuration can arm and
disarm the system, send reports, and perform all system functions except one-time disarm and change PINs.
Authority Level 3 (User): All options except for Options 5, 7, 8, and 10 to 14. A user with this authority level configuration
can arm and disarm the system, send reports, but can only perform a limited number of system functions.
Authority Level 4 (One-Time): All options except 7 to 15. A user with this authority level configuration can arm and disarm
the system (one-time only), send reports, but can only perform a limited number of system functions and cannot force-arm or
bypass zones when arming the system.