DS7200V2-UK Installer's Guide Copyright 2007 Bosch Security Systems, Inc. P/N: 4998152533-02 Page 85
PART IV: CONTROL PANEL PROGRAMMING
Bell Time
Address: 1040
Default: 10
Selections: 0-15 (1-minute increments)
Bell Time determines how long, 0 to 15 minutes, the Alarm Output, Fire Alarm Output and Silent Alarm Output functions
remain activated when triggered by an alarm event.
Siren Warble Frequency
Address: 1041
Default: 7
Selections: 0 (lowest tone/frequency) to 15 (highest tone/frequency)
This parameter sets the siren warble frequency for non-fire alarm output functions.
Programmable Output 2 (PO 2) can be configured as a supervised horn/speaker output (see
Global Output Options on page
84).
This parameter sets the warble frequency for the alarm output functions (1|8, 1|9, 1|10, and 8|8). The setting chosen here does
not apply to other output functions.
Lowering the frequency effectively raises the perceived volume.
Siren Output Volume
Address: 1042
Default: 7
Selections: 0 (no sound) to 15 (loudest); 1 = quiet)
PO 2 can be configured as a supervised horn/speaker output (see
Global Output Options on page 84).
This parameter sets the perceived volume for the Alarm Output Arming Beep.