14 en | Appendix Easy Series Control Panel
2017.01 | 02 | F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH
System Programming Items
Item
No.
Programming Item Range
124 Point Alarm
Verification
0 = Off
1 = Cross Zone
2 = Intelligent Threat Assessment
3 = Confirmed Alarms 1 (initial entry door)
4 = Confirmed Alarms 1 (token, key fob, or
keyswitch)
125 Faulted Points
Allowed Threshold
0 to 8
126 Exit Delay 0 to 255 sec
127 Entry Delay 0 to 255 sec
129 Recent Close Enabled 0 = Report not sent
1 = Report sent
131 Swinger Bypass Count 0 to disable, 1-15
133 System On Order
Options
1 to 6
134 Cross Zone Timer 0 to 3600 sec
136 Clear Alarm Memory 0 = By any user
1 = By master user only
140 Demo Mode 0 = The system only speaks all telephone
messages over the phone.
1 = The system speaks all telephone
messages over the phone and at all control
centers connected to the system.
2 = During telephone programming, press
the [i] button to turn message
announcements on or off at the control
center.
142 Restrict Installer
Passcode
0 = Master user not needed
1 = Master user needed
151 Wireless Device
Supervision Interval
1= 1 Hour
2= 2 Hours
3= 4 Hours
4= 12 Hours
5= 24Hours
6= 2.5 Hours
162 Missing Wireless
Device Conditions
0 = Missing conditions create a tamper
condition (meets EN50131).
1 = Missing conditions create a trouble
condition.

Other manuals for Bosch Easy Series