Easy Series Control Panel Appendix | en 15
Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 | 02 | F.01U.306.216
System Programming Items
Item
No.
Programming Item Range
163 Silence Trouble Tones 0 = All trouble tones beep at the control
center.
1 = Only Fire and 24-Hour trouble tones
beep at the control center.
164 System Inactivity Time
(Hours)
Enter the number of hours (0-255) that the
system must be off before it sends the
System Inactive report.
165 System Inactivity Time
(Days)
Enter the number of days (0-255) that the
system must be off before it sends the
System Inactive report.
166 System Inactivity Time
(Weeks)
Enter the number of weeks (0-255) that the
system must be off before it sends the
System Inactive report.
167 Force Arm/Exit Error 0 = Off-normal points create an exit error at
the end of Exit Delay
1 = Off-normal points are force-armed at the
end of Exit Delay
168 Audio Verification
Command Set
0 = Use SIA Standard Audio Verification
commands (AV-01-1997.11)
1 = Use alternate audio verification
command set
601 Enable Keyfob Duress 0 = Wireless keyfob does not send a Duress
event
1 = Wireless keyfob sends a Duress event
Audio Verification Commands
SIA Standard Audio Verification Commands (Item No. 168 = 0)
Phone Button Command
[1] Talk to premises.
[3] Listen to premises.
[6] Listen to premises.
[7] Restart 90-second timer.
[9][8] Terminate session with call back.
[9][9] Terminate session without call back.
[0] Listen to all microphones.
[#] Cancels first digit of command.