44 en | Configuration DINION 5100i IR
2023-08 | V01 | F.01U.393.997
User manual
Bosch Security Systems B.V.
SMTP password
Enter the required password for the registered user name.
Format
Select the data format of the alarm message.
– Standard (with JPEG): e‑mail with JPEG image file attachment.
– SMS: e‑mail in SMS format to an e‑mail‑to‑SMS gateway without an image attachment.
When a mobile phone is used as the receiver, make sure to activate the e‑mail or SMS
function, depending on the format, so that these messages can be received. Obtain
information on operating your mobile phone from your mobile phone provider.
Image size
Select the size of the JPEG images that are to be sent from the camera.
Attach JPEG from camera
To send a JPEG image from a particular video channel, check the appropriate box.
VCA overlays
Select the VCA overlays check box, to place the outline of the object that triggered an alarm
into the camera image sent as snapshot via e-mail.
Destination address
Enter the e‑mail address for alarm e‑mails here. The maximum address length is 49 characters.
Sender address
Enter a unique name for the e‑mail sender, for example, the location of the device. This makes
it easier to identify the origin of the e‑mail.
Test e-mail
Click Send Now to test the e‑mail function. An alarm e-mail is immediately created and sent.
Click Set to apply the changes.
4.6.5 Alarm Inputs
Active
Configure the alarm triggers for the unit.
Select N.C. (Normally Closed) if the alarm is to be triggered by opening the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by closing the contact.
Name
Enter a name for the alarm input. This is then displayed below the icon for the alarm input on
the Live page (if configured).
Action
Select a type of action to be performed when an alarm input occurs:
– None
– Monochrome
This switches the camera to the monochrome mode.
– Switch mode
When this is selected, you can select the Scene Mode to be used for the active and
inactive period of the alarm.
Click Set to apply the changes.
4.6.6 Alarm Outputs
Configure the switching behavior of the output.
Select different events that automatically activate an output. For example, turn on a floodlight
by triggering a motion alarm and then turn the light off again when the alarm has stopped.