22 en | Configuration DINION 5100i IR
2023-08 | V01 | F.01U.393.997
User manual
Bosch Security Systems B.V.
Note: Clicking this button also clears the service-level password. Operators must reset the
password before doing anything else.
4.4.2 Display Stamping
Various overlays or stamps in the video image provide important supplementary information.
These overlays can be enabled individually and arranged on the image in a clear manner.
The drop-down menus below allow the configuration of the individual stamping options. The
respective sample windows show a preview of the configured text and background styles.
Click Set to apply the changes.
Global configuration
i
Notice!
These options can also be configured individually for all stamping settings.
Any changes to the global configuration settings will be applied to all stamping settings!
Stamping size
Select the desired font size of the overlays on the OSD: Normal, Large or Custom.
Select Custom to enable the Font size (‰) field.
Text color
Select the color for the alarm message to be displayed in.
Background color
Select the background color for the alarm message to be displayed in.
If you have enabled the Transparent background option, the background color is not
displayed in the OSD.
Camera name stamping
Position
Select the position of the camera name overlay in the drop-down box. It can be displayed at
the Top, at the Bottom, or at a position of choice using the Custom option, or it can be set to
Off for no overlay information.
If the Custom option is selected, enter values in the X and Y position fields.
Stamping size
Select the desired font size of the overlays on the OSD: Normal, Large or Custom.
Select Custom to enable the Font size (‰) field.
Text color
Select the color for the alarm message to be displayed in.
Background color
Select the background color for the alarm message to be displayed in.
If you have enabled the Transparent background option, the background color is not
displayed in the OSD.
Optionally, tick the Underlay with full-width bar box to place a full-width background-bar
beneath the time stamp.
i
Notice!
Camera / video names can be changed under General > Identification.