14 Connection
Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2–6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.
Note: Consult the National Electrical Code (NEC) for cable bundling requirements and
limitations.
4 Connect the cable to the 24 VAC wires from the camera.
Label ID Description Cable Wire Color
AC24V 24 VAC Red
AC24V 24 VAC Black
EARTH Earth Ground Yellow/Green
4 Connect the Ethernet cable to the RJ45 connector of the camera. The following figure
illustrates a typical system configuration.
Figure14.1: AUTODOME IP System Config
1 AUTODOME camera
2 IP connection (Ethernet/CAT5/CAT6) (100 m maximum)
3 Network switch
4 Network device (computer with monitor, DVR/NVR, etc.)
4 If desired, connect the alarm and/or audio wires as identified in the following table.
Label ID Description Cable Wire Color
ALARM_COM Alarm Communications Red
ALARM_OUT Alarm Out Brown