Professional Series TriTech AM Motion Detectors
with Anti-mask, LSN
Configuration | en 19
Bosch Building Technologies Reference Manual 2018.10 | 01 | F.01U.352.414
8 Configuration
Selecting the detector configuration setups are done using the control panel's supported
remote programming software. The remote programming software allows you to enable or
disable the configuration setups by selecting the appropriate menu options within the
software.
Accessing through MAP RPS
1. Launch MAP 5000 RPS program.
2. Open Hardware Manager.
3. Expand Internal BDB menu tree.
4. Expand [LSN GW 1] menu tree.
5. Find Dual PIR option under Toolbox.
6. Click and drag [LSNPro/PDL1-WA18x/WAC25x LSN from Toolbox to the LSN loop box.
7. Right-click, and select Properties.
8. Scroll down and find Misc to find the configuration setups. (for example, Anti-mask
Detection, Anti-mask Latched, Detection Range).
Notice!
A description of the configuration setup appears when you select it in the field below the
configuration setup selection.
8.1 Classic/LSNi mode
8.1.1 Classic mode
Classic Mode was first introduced with traditional LSN configuration setups. The address for
the detector is not set by selecting the LSN address switch, but is automatically assigned an
address on the bus by the supporting control panel. The address range is restricted up to a
range of 127.