EasyManua.ls Logo

Bosch Rexroth 3 Series - Page 36

Bosch Rexroth 3 Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36/68 Installation
Bosch Rexroth AG, A4CSG, Series 3x, RE 92105-01-B/06.2017
2
2
1
1
2
1
Fig. 11: Removing transport protection
1 Protective covers 2 Protective plugs/threaded plugs
Ports intended for connecting lines are provided with protective plugs or
threaded plugs, which serve as transport protection. All ports required for
functional operation must be connected (see Table 10 “Ports A4CSG series 1x
and 3x” on page 39). Failure to do so could lead to malfunctions or damage. If
a port is not connected, it must be plugged with a threaded plug because
protective plugs are not pressure-resistant.
The setting screws are protected against unintentional adjustment by caps.
Adjusting the setting screw will void the warranty. If you need to change settings,
contact your Bosch Rexroth service partner, for the address, see chapter 10.4
“Repair” on page 54.
3. For versions with through drive, assemble the auxiliary pump according to the
pump manufacturer's instructions.

Table of Contents

Related product manuals