2 Ratings and dimensions
2.1 KMV03
2.1.1 KMV03 ratings
UL ratings and dimensions
Description Symbol Unit
KMV03.1R-
A05K0-P-D7-
ET-NNNN
KMV03.1R-
B0007-P-D7-
ET-NNNN
KMV03.1R-
I01K5-P-D7-
ET-NNNN
KMV03.1R-
W06K0-P-D7-
ET-NNNN
Listing according to UL standard UL 61800-5-1
Listing according to CSA standard CSA C22.2 No. 274-13
UL‑Files E134201
Pollution degree 2
Ambient temperature range with
nominal data
T
amax
°C 40
Ambient temperature range with
reduced nominal data
T
amax_red
°C 55
Mass m kg 20.00 15.70 20.00
Device height
1)
H mm 360 280 360
Device depth
2)
T mm 280 230 280
Device width
3)
B mm 330 325 330
Minimum distance on the top of
the device
d
top
mm 0
Minimum distance on the bottom
of the device
d
bot
mm 0
Horizontal spacing at the device
d
hor
mm 0
Rated control voltage input
8)
U
N3
V DC 24 V ±20 %
Rated power consumption control
voltage input at U
N3
and
P
out
= 0 W
P
N3
W 18
Rated voltage
U
out
V 42
Nominal power
P
out
W 340 510 200 400
Short circuit current rating SCCR A rms 42000
Rated input voltage, power
4)
U
LN_nenn
V 3x AC 380…500
Tolerance rated input voltage U
LN
% ±10
Mains frequency
f
LN
Hz 50...60
Tolerance input frequency Hz ±2
Rated input current
I
LN
A 8.1 12.0 2.3 9.5
Branch circuit protection fuse
5)
A 15 15 6 15
IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter
5/29
Ratings and dimensions
R911374765_Edition 01 Bosch Rexroth AG