18/36 Valve amplifier VT-MSPA2-2X | Commissioning
BOSCH REXROTH AG, Edition 02.2021, RE 30232-02-B
7.5.4 Suppressing interference of the system
Should interference occur in conjunction with signals of the VT-MSPA2-2X, check
the interference suppression of other electrical components, e.g. as follows:
Table 9: Suppressing interference
Possible causes of faults
Switched inductance DC: antiparallel free-wheeling diode over actuator winding
AC: type-related R/C combination over actuator winding.
Electric motors R/C combination from each motor winding to earth.
Frequency converter Inlet filter in the voltage supply of the frequency converter
Motor control lines shielded and installed separately from other
cables and/or output filter for motor cables.
Large-area contact of the frequency converter housing to the
rear wall of the control cabinet
8 Commissioning
NOTICE
Uncontrolled plugging and unplugging of connectors!
The device might be destroyed.
Before plugging or unplugging connectors into or from the device, disconnect
the device from the power supply or de-energize it reliably!
Damage to the device caused by incorrect handling is not covered by the
warranty!
Observe the protection class, the voltage supply and the environmental
conditions according to data sheet RE 30232-02.
For commissioning we recommend using a multimeter.