EasyManua.ls Logo

Bosch Rexroth VT-VSPA2-1-2X Series - Troubleshooting; How to Proceed for Troubleshooting

Bosch Rexroth VT-VSPA2-1-2X Series
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Extension and modification 35/40
RE 30110-B/11.2012, VT-VSPA2-1-2X/V0/T., Bosch Rexroth AG
12 Extension and modification
The VT-VSPA2-1-2X amplifier card must neither be extended nor converted. If you
convert the VT-VSPA2-1-2X amplifier card, warranty will expire.
13 Troubleshooting
13.1 How to proceed for troubleshooting
Always work systematically and targeted, even when under time pressure. Random,
thoughtless disassembly and changing of settings can, in the worst-case-scenario,
result in the inability to determine the original error cause.
First get a general idea of how your product works in conjunction with the over-
allsystem.
Try to find out whether the product has worked properly in conjunction with the
overall system before the error occurred first.
Try to determine any changes of the overall system in which the product is integrated:
Were there any changes to the product's application conditions or area ofapplication?
Were there any changes (e. g. refittings) or have repairs been carried out at the
overall system (machine/system, electrical systems, control) or at the product?
If so: What were they?
Was the product or machine used as intended?
How did the fault become apparent?
Try to get a clear idea of the cause of the error. Ask the direct (machine) operator.
If you could not remedy the occurred error, please contact one of the addresses
you find at www.boschrexroth.com or in the list of addresses in the appendix.

Table of Contents