FIRE ALARM: Fire alarm at point in area specified.
FIRE END: Fire Walk Test ended.
FIRE RSTOR: Fire alarm at point specified restored.
FIRE TRBLE: Trouble condition at point specified.
FIRE START: Fire Walk Test started.
FORCE ARMD: Beginning of force arm report. Indicates area was force armed, bypass armed, or
force/bypass armed. This event followed by events showing the points force armed and/or
bypassed, and by a FORCE CLSE event showing the end of the forced armed report.
FORCE CLSE: Indicates end of forced armed report. Followed by an event modifier showing the
previous armed state.
FORCE PT: Event modifier showing user force armed with point specified faulted.
LATE: Event modifier for arming (close) and disarming (open) events. Indicates the open or close
event occurred after the end of an open or close window.
LOG FULL: Panel log is full. New event overwrite oldest event.
LOG THRES: Panel log reached programmed threshold (Log % Full).
MISS ALARM: Point in area specified missing. Area armed.
MISS FIRE: Fire point specified missing.
MISS TRBLE: Point in area specified missing. Area disarmed.
NEW TIME: Event modifier for XTN event. Shows the new time for end of close window.
OPEN: User disarmed area. An event modifier showing the previous armed state follows this event in
the log. If an open window is in effect, a second event modifier shows if the disarming (open)
was outside of the open window.
PARAM CHG: Panel programming changed.
PERM DLY: User armed the perimeter of the specified area with entry delay time. An event modifier
showing the previous armed state follows this event in the log. If a close window is in effect, a
second event modifier shows if the arming (close) was outside of the close window.
PERM INS: User armed the perimeter of the specified area with no delay time. An event modifier
showing the previous armed state follows this event in the log. If a close window is in effect, a
second event modifier shows if the arming (close) was outside of the close window.
PHONE FAIL: Panel detected phone line specified as faulted.
PHONERSTOR: Phone line specified detected as restored from faulted condition.
PROG: Event modifier for BYPASS, RELAY SET, and RELY RESET events. Indicates function initiated
from local programmer.
PROG BAD: Attempt to access panel with a local programmer failed.
PROG OK: Panel successfully programmed by a local programmer.
PT CLOSE: User armed point specified.
PT OPEN: User disarmed point specified.
PT STATUS: Status report for point specified.
PT TESTED: This point walk tested.

Other manuals for Bosch Security System

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Security System and is the answer not in the manual?

Bosch Security System Specifications

General IconGeneral
BrandBosch
CategorySecurity System
AlertsEmail, SMS, Push notifications
Remote AccessMobile app
EncryptionAES-128
Warranty2-3 years

Related product manuals