Log Event Definitions
AC FAIL: AC power to the panel interrupted.
AC RSTOR: AC power to the panel restored.
ALARM: Alarm at point in area specified.
AUTO: Event Modifier for BYPASS event. Indicates 4 alarms or troubles in one clock hour caused
automatic (swinger) bypass.
BAD CALL: System tried to call Remote Account Manager and failed.
BATT LOW: Panel battery is below 11.7 VDC.
BATT MISS: Panel battery disconnected or discharged.
BATT RSTOR: Panel battery recharged.
BUS RSTOR: Data Expansion Loop for off-board points restored.
BUS TRBLE: Data Expansion Loop for off-board points faulted.
BYPASS: Point bypassed. An event modifier showing how the point was bypassed follows this event
in the log.
CANCEL: User canceled an alarm from the area specified.
CKSUM FAIL: Panel programming corrupted. Call for service.
CLOSE: User armed area. An event modifier showing the previous armed state follows this event in
the log. If a close window is in effect, a second event modifier shows if the arming (close) was
outside of the close window.
CODE CHG: Passcode changed for user number shown.
CODE DEL: Passcode deleted for user number shown.
CODE TMPR: User made six failed attempts to enter a passcode at a command center.
COMMAND: Event modifier for BYPASS, RELAY SET, and RELY RESET events. Indicates function
initiated from a command center.
COMM FAIL: Panel could not communicate using phone line reported.
COMM RSTOR: The communication problem with the phone line indicated resolved.
DATE CHG: User changed panel’s date and/or time.
DURESS: User initiated from command center special alarm in the area specified.
EARLY: Event modifier for arming (close) and disarming (open) events. Indicates the open or close
event occurred before the beginning of an open or close window.
EXTRA PT: Incorrectly programmed point connected to system.
F PERM DLY: User force armed area specified with delay. An event modifier showing the previous
armed state follows this event in the log. If a close window is in effect, a second event modifier
shows if the arming (close) was outside of the close window.
F PERM INS: User force armed area perimeter with no delay time. An event modifier showing the
previous armed state follows this event in the log. If a close window is in effect, a second event
modifier shows if the arming (close) was outside of the close window.
FAIL CLOSE: Area not armed before end of close window.
FAIL OPEN: Area not disarmed before end of open window.

Other manuals for Bosch Security System

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Security System and is the answer not in the manual?

Bosch Security System Specifications

General IconGeneral
BrandBosch
CategorySecurity System
AlertsEmail, SMS, Push notifications
Remote AccessMobile app
EncryptionAES-128
Warranty2-3 years

Related product manuals