EasyManuals Logo

Bosch Singular 5200 Installation Instructions

Bosch Singular 5200
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
62
|
Installation Instructions
Singular Combi Boiler - BTC 439003301 B (2021/07)
16.2 Cleaning the Cold Water Inlet Filter
To clean the cold water inlet fi lter:
1. Drain the boiler. Refer to Section 16.1 "
Draining the Boiler    
".
2. Remove the cold water inlet fi lter from the boiler.
Figure 98
3. Rinse the cold water inlet fi lter with clean running water.
4. Reinsert the cold water inlet fi lter.
5. Refi ll the boiler. Refer to "
Draining the Boiler    
" on page 60.
16.3 Cleaning the Air Intake Filter
To maintain the boiler properly, clean the air intake fi lter every 2–3 months. If the
air intake fi lter is clogged by dust or lint, the boiler will cease to operate or error can
occur.
To clean the air intake fi lter:
1. Press the button to turn off the boiler.
2. Disconnect the power supply to the boiler.
3. Remove the boiler front cover by loosening the 2 Phillips screws securing it
to the case.
Figure 99
1
1
2
2
4. Remove the air intake fi lter located under the air intake connector.
Figure 100
Air intake lter
5. Rinse the air intake fi lter with clean running water.
6. Dry the air intake fi lter completely.
7. Reinsert the air intake fi lter and replace the front cover.

Table of Contents

Other manuals for Bosch Singular 5200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Singular 5200 and is the answer not in the manual?

Bosch Singular 5200 Specifications

General IconGeneral
BrandBosch
ModelSingular 5200
CategoryBoiler
LanguageEnglish

Related product manuals