Installation Instructions
Singular Combi Boiler - BTC 439003301 B (2021/07)
2.4 Rating Plate
WARNING: FIRE, EXPLOSION
The gas type and electricity voltage must match the rating
plate. Using a different gas type and electricity voltage will
cause the boiler to malfunction.
Before the installation, check the rating plate located on the side of the boiler to
ensure that the boiler matches the gas type, gas pressure, water pressure, and
electrical supply available in the installation location. If the boiler does not match
each of these ratings, do not install the boiler. If the gas conversion is required, the
included gas conversion kit must be used.
Figure 3
Natural Gas
0.
Certied to
NSF/ANSI 372
Combination Boiler and Space Heater / Combiné Chaudière et Chaue-Espace
For either direct vent installation or for installation using indoor combustion air .
/Pour une installation à évacuation directe ou pour une installation utilisant de l'air de combustion à l'intérieur .
Natural Gas
Heating Capacity
Capacité de chauffage
3.5~10.5
210
Edition of the standard : ANSI Z21.13-2017. CSA 4.9-2017, Low Pressure Boiler
Orices necessary for LP conversion are provided.
Les injectures nécessaires à la conversion au GPL sont fournis.
For installation on noncombustible oors only . /Pour l'installation sur des sols incombustibles uniquement.
Water temperature limit
limite de température de l'eau
M/C No. 271266
of
This boiler must be installed in accordance with local codes, if any; if not, follow the National Fuel Gas Code , ANSI
Z223.1/NFP A 54, or the Natural Gas and Propane Installation Code , CAN/CSA B149.1, as applicable.
Cette chaudière doit être installée conformément aux codes locaux, le cas échéant. Sinon, respectez le code national de gaz
combustible, ANSI Z223.1 / NFPA 54, ou le code d'installation de gaz naturel et propane, CAN/CSA B149.1, selon le cas.
This boiler must be installed with vent the vent-air intake system as specied and installed in accordance with the
Cette chaudière doit être installée de manière à purger le système d’admission d’air-air comme spécifié et installée
manufacturer ’s installation instructions.
conformément aux instructions d’installation du fabricant.
When reinstalling the appliance, check the sealing on the exhaust & air intake vent system.
Lors de la réinstallation de l'appareil, vérifiez l'étanchéité du système de ventilation d'échappement et d'admission d'air.
50 W entworth Ave, Londonderry , NH 03053
~
Bosch
Bosch Thermotechnology Corporation
- 866-642-3198
The pressure relief valve provided by the manufacturer shall
Valve shall be placed in suitable area where it will not cause
doit
damage.
(La vanne doit être placée dans un endroit approprié où
elle ne causera pas de dommages.)
Bosch.
Bosch.
en haute de
Corée du Sud

Table of Contents

Other manuals for Bosch Singular 5200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Singular 5200 and is the answer not in the manual?

Bosch Singular 5200 Specifications

General IconGeneral
BrandBosch
ModelSingular 5200
CategoryBoiler
LanguageEnglish

Related product manuals