Horizontal Configurability | 9SM Series Heat Pump
6 720 220 406 (2015/02)Revised 02-15
9. Remove and discard blower collar by removing
(8) screws. (Figure #14)
Figure # 14
10. Reorient the blower assembly 180 degree with
blower “belly” down and slide back into the
cabinet. (Figure #15)
Figure # 15
11. Reinstall bracket in the new vertical position
using (2) screws. (Figure #16)
Figure # 16
12. Reinstall bracket removed in step (#3) using
(3) screws in the same location. (Figure#17)
Figure # 17
13. Reinstall remaining bracket using (2) screws.
(Figure#18)
Figure # 18
14. Connect vertical and horizontal brackets by
installing (4) screws. (Figure#19)
Figure # 19
15. Reconnect blower motor wiring and ground
wire.
1
2
1
2