NLTroubleshooting
Malfunction Cause and Troubleshooting
5.Remove the strainer from the inlet hoseE:32-00 lights up alternately
selend or indication
for water supply
burns.
6.Clean the strainer.
7.Place the strainer in the inlet hose.
8.Screw the water connection.
9.Check the water connection for leaks.
10.Put the plug back in the socket.
11.Turn on the device.
E:34-00 lights up alternately
selend.
Water flows continuously into the appliance.
1.Close the tap.
2.Contact the service department
→
Page 54
.
E:61-02 lights up alternately
selend.
No device error. Water drain pump is blocked or cover
of water drain pump is loose.
1.Clean the drain pump.
→
"Clean the drain pump", page 52
2.Tighten the drain pump cover securely.
→
"Clean the drain pump", page 52
Remark:This is not a fault of the device. The device has
detected a problem with pumping down. The problem
can most likely be corrected by the user or the installer.
We point out that errors by the user or by
tallation are not covered by the warranty and
will be brought.
the ins
in rack