System Options 3
Item Location Option Default New
System Options 3 0494 1 = AC fail after 1 hr. (Disabled = after 2 min.)
2 = Ignore AC fail
4 = Pulse count handover allowed
8 = Handover delay to be sequential
8
System Options 4
Item Location Option Default New
System Options 4 0495 1 = Panel to power up disarmed (if power
reset)
2 = Arm/disarm tracking on power up
4 = Reserved
8 = Reserved
2
Consumer Options 1
Item Location Option Default New
Consumer Options 1 0496 1 = Test reports only when armed
2 = Test report after siren reset
4 = Auto arm in STAY Mode 1
8 = STAY indicator to display day alarm status
0
Consumer Options 2
Item Location Option Default New
Consumer Options 2 0497 1 = Codepad displays extinguish after 60 sec.
2 = Single button arming allowed (AWAY/STAY
Modes 1 and 2)
4 = Single button disarming allowed (STAY
Modes 1 and 2)
8 = Alarm memory reset on disarm
2
Consumer Options 3
Item Location Option Default New
Consumer Options 3 0498 1 = Codepad fault beeps allowed
2 = Use digit 3 for codepad duress alarm
(instead of digit 9)
4 = Alarms activate sirens and strobe outputs
in STAY Modes 1 and 2
8 = Zone tamper alarms to be silent
5
4.15.3
4.15.4
4.15.5
4.15.6
4.15.7
42 en | Programming Parameters Control Panel
2015.06 | 03 | F.01U.298.027 Quick Reference Guide Bosch Security Systems, Inc.