Item Location Default New Item Location Default New
Zone Pulse Count 0352 0 Zone Pulse Count 0359 0
Zone Pulse Count Time 0353 0 Zone Pulse Count Time 0360 0
Zone Options 1 0354 1 Zone Options 1 0361 1
Zone Options 2 0355 14 Zone Options 2 0362 14
Reserved 0356 Reserved 0363
Zone Report Options 0357 1 Zone Report Options 0364 1
Zone #15 Zone #16
Zone Type 0365 15 Zone Type 0372 15
Zone Pulse Count 0366 0 Zone Pulse Count 0373 0
Zone Pulse Count Time 0367 0 Zone Pulse Count Time 0374 0
Zone Options 1 0368 1 Zone Options 1 0375 1
Zone Options 2 0369 14 Zone Options 2 0376 14
Reserved 0370 Reserved 0377
Zone Report Options 0371 1 Zone Report Options 0378 1
For zone item options, refer to below Zone Item Options.
Item Option
Zone Type 0 = Instant
1 = Handover
2 = Delay-1
3 = Delay-2
4 = Reserved
5 = Reserved
6 = 24-Hour Medical
7 = 24-Hour Panic
8 = 24-Hour Hold-up
9 = 24-Hour Tamper
10 = Reserved
11 = Keyswitch
12 = 24-Hour Burglary
13 = 24-Hour Fire
14 = Chime Only
15 = Not used
Zone Pulse Count Use the pulse count to program how many pulses (0 to 15) need to
be registered within the pulse count time to activate an alarm.
Zone Pulse Count Time 20 ms Loop Response Time 150 ms Loop Response Time
0 = 0.5 sec.
1 = 1 sec.
2 = 2 sec.
3 = 3 sec.
4 = 4 sec.
5 = 5 sec.
6 = 10 sec.
7 = 15 sec.
8 = 20 sec.
9 = 30 sec.
10 = 40 sec.
11 = 50 sec.
12 = 60 sec.
13 = 90 sec.
14 = 120 sec.
15 = 200 sec.
Control Panel Programming Parameters | en 29
Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)