EasyManua.ls Logo

Bosch SOLUTION 3000 - Codepad Address Setting

Bosch SOLUTION 3000
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Callout --Description Callout --Description
1 – Socket for telecom lead connect 8 – Bosch SDI2 Bus
2 – Receiver interface connection 9 – Battery input
3 – Tamper switch 10 – Plug pack input (Bosch TF008)
4 – Zone 5-8 termination strip
( Zone 5 – 8 and Zone 13 – 16 for Solution
3000 )
11 - Bosch SDI2 Bus
5 – AUX power 12 – Relay contact select (Select output AUX
as shown or output GND)
6 – Zone 1-4 termination strip
( Zone 1 - 4 and Zone 5 – 8 for Solution
2000 ;
Zone 1 – 4 and Zone 9 – 12 for Solution
3000 )
13 – LED indicator
7 – Output termination strip 14 – Default button
Table 5.5: Callout description
Codepad Address Setting
DIP Switch Codepad
Address
DIP Switch Number
1 2 3 4 5 6
1 On Off Off Off Off On
2 Off On Off Off Off On
3 On On Off Off Off On
4 Off Off On Off Off On
Table 5.6: Codepad DIP switch address setting
DIP switch address settings are only for IUI-SOL-TEXT or IUI-SOL-ICON codepad.
5.4
Control Panel Appendices | en 51
Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027