EasyManuals Logo

Bosch SOLUTION 3000 Quick Reference Guide

Bosch SOLUTION 3000
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Item Option
Event Code 0 0 = Reserved
0 1 = System armed
0 2 = System disarmed
0 3 = Armed in STAY mode
0 4 = Armed in AWAY mode
0 5 = Pre-arming alert
0 6 = Exit Warning (all zones sealed) and
entry warning
0 7 = Exit Warning
0 8 = Exit Warning finished
0 9 = Kiss-off after end of Exit Time
0 10 = Reserved
0 11 = Entry warning
0 12 = Entry warning and day alarm resetting
0 13 = Exit warning and entry warning and
day alarm resetting
0 14 = Day alarm resetting
0 15 = Day alarm latching
1 0 = Day alarm enabled
1 1 = Telephone line fail
1 2 = Kiss-off received
1 3 = AUX Power Supply fail
1 4 = AC fail
1 5 = Low battery
1 6 = Output 1 fail
1 7 = Sensor watch alarm
1 8 = Codepad medical alarm
1 9 = Codepad fire alarm
1 10 = Codepad panic alarm
1 11 = Codepad duress alarm
1 12 = Access denied (code retries)
1 13 = Reserved
1 14 = Horn speaker (output 1 only)
1 15 = Siren running
Event Code
2 0 = Strobe
2 1 = Silent alarm
2 2 = Alarm in STAY mode
2 3 = Alarm in AWAY mode
2 4 = System fault
2 5 = Fire alarm (resetting)
2 6 = Fire alarm (latching)
2 7 = Fire alarm (verification)
2 8 = Remote control 1
2 9 = Remote control 2
2 10 = Remote control 3
2 11 = Radio control output 1
2 12 = Radio control output 2
2 13 = Radio control output 1- not in AWAY
Mode
2 14 = Radio control output 2- not in AWAY
Mode
2 15 = Communications fail after 3 attempts
3 0 = Communications fail
3 1 = Report disabled
3 2 = Report active (on-line)
3 3 = Ring detect
3 4 = Codepad/Keyfob panic
3 5 = Mimic zone 1
3 6 = Mimic zone 2
3 7 = Mimic zone 3
3 8 = Mimic zone 4
3 9 = Mimic zone 5
3 10 = Mimic zone 6
3 11 = Mimic zone 7
3 12 = Mimic zone 8
3 13 = Reserved
3 14 = Reserved
3 15 = Reserved
Control Panel Programming Parameters | en 37
Bosch Security Systems, Inc. Quick Reference Guide 2015.06 | 03 | F.01U.298.027

Table of Contents

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
Partitions2
Event Log256 events
Power Supply16.5 VAC, 40 VA
Zones8
Users32
Remote AccessYes, via app
CommunicationPSTN
Battery Backup12V
Programmable Outputs2 (expandable)

Related product manuals