Control Panel Operation with ICON LCD Codepad | en 23
Bosch Security Systems, Inc. User's Guide 2017.09 | 04 | F.01U.298.028
1. Enter your Master Code, followed by the [7] and [#] keys (for example, [25807#]). Three
beeps sound, and the STAY and AWAY indicators flash. The codepad beeps once every
sec while the system is in Walk Test Mode.
2. Activate all zones requiring the test.
3. When you finish testing all required zones, press the [#] key to exit from this mode. Two
beeps sound, and the STAY and AWAY indicators turn off. The system returns to the
disarmed state.
5.12.5 Test Report
This feature applies if your system reports using the telephone or network modules. By
holding down the [9] key until two beeps sound, the system sends a Test Report.
5.13 Event Memory
Use this function to replay the last 256 events that the system recorded. The event memory
history replays all alarms and the arming/disarming of the system in AWAY Mode, STAY Mode
1, and STAY Mode 2. However, the event memory history can replay system faults on the TEXT
codepad, but not on the ICON codepad.
How to Enter Event Memory
Enter your Master Code, followed by[8] and the [#] button (for example, [25808#]). Three
beeps sound. The last 256 events display one at a time by the codepad indicators, starting
with the most recent event. A beep sounds as each event displays.
5.14 Day Alarm
Day alarm monitors a combination of zones during the disarmed state. It beeps the codepad
buzzer if activated. Only your installer can program zones 1 to 4 to operate for day alarm.
Example
A day alarm can be configured for the front door of a shop with a pressure mat or electronic
beam that customers activate as they enter the shop. When customers step on the pressure
mat or break the electronic beam, the codepad buzzer beeps.
How to Turn Day Alarm On
Hold down the [4] key until three beeps sound. Day alarm turns on. All zones programmed for
day alarm operation cause the codepad buzzer to beep during the disarmed state when
activated.
How to Turn Day Alarm Off
Hold down the [4] key until two beeps sound. Day alarm turns off.
5.15 Codepad ID / Buzzer Tone
1. Hold down the [8] key until the desired buzzer tone is reached.
– If the system is partitioned, the codepad displays a number identifying which area the
codepad belongs (See below table).
2. Press the [#] key to exit.
There are 50 different tones, from1500 Hz to 5000 Hz. If multiple codepads are installed, each
codepad can have a different tone.

Other manuals for Bosch SOLUTION 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 3000 and is the answer not in the manual?

Bosch SOLUTION 3000 Specifications

General IconGeneral
BrandBosch
ModelSOLUTION 3000
CategoryControl Panel
LanguageEnglish

Related product manuals