EasyManua.ls Logo

Bosch TriTech - 6 Wiring

Bosch TriTech
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commercial Series TriTech and TriTech AM
detectors
Wiring | en 17
Bosch Security Systems B.V.
Installation manual
2022.01 | 01 | F.01U.401.708
6 Wiring
!
Caution!
Apply power only after you have made and inspected all connections. Do not coil excess
wiring inside the motion detector.
6.1 Wiring overview
TriTech AM terminal block strip
NC NC
T
T
TRTR
1
2
3
4
RLED
Callout — Description
1 — Input power terminals. Voltage limits are 9 to 15 VDC. Use no smaller than 0.4 mm (26
AWG) wire pair between the detector and the power source.
2 — Alarm terminals. Solid State output. Normally closed relay rated at 25 VDC, <35 mA, 2.5
W. Do not use with capacitive or inductive loads.
3 — Tamper terminals. Normally closed switch rated at 25 VDC, <25 mA, 2.5 W.
4 — Trouble terminals. Solid State output. Normally closed relay rated at 25 VDC, <35 mA,
2.5 W. Do not use with capacitive or inductive loads.

Table of Contents