Commercial Series TriTech and TriTech AM
detectors
Configuration | en 33
Bosch Security Systems B.V.
Installation manual
2022.01 | 01 | F.01U.401.708
If you do not want the LED to light when the device detects a possible alarm event, disable
the LED after you complete the walk test.
Notice!
Some regulations require that you disable the LED after the walk test.
Automatic brightness
To improve LED visibility in any lighting environment, the walk test LED automatically changes
brightness. In dark environments, the LED intensity lessens; in bright environments, the LED
intensity increases.
7.4 Adjustable Cloak and Camouflage Detection Technology
sensitivity
The detector includes two Cloak and Camouflage Detection Technology (C
2
DT) sensitivity
modes: high and low.
– High sensitivity. The recommended setting for any location where an intruder might cover
only a small portion of the protected area. C
2
DT tolerates normal environments on this
setting. This setting improves catch performance.
– Low sensitivity. The recommended setting for maximum false alarm immunity. C
2
DT
tolerates environmental extremes on this setting.
2
2
High
cDT EN Grade3 [TriTechAM]
cDT EN Grade2 [TriTech]
cDT EN Grade2 [TriTechAM]
Low
ON
1 2 3
7.5 TriTech Anti-mask
Notice!
TriTech Anti-mask option
This option is for TriTech AM models only.