32 en | Configuration
Commercial Series TriTech and TriTech AM
detectors
2022.01 | 01 | F.01U.401.708
Installation manual
Bosch Security Systems B.V.
If the detector is in a self test fault condition, the LED
flashes 4 times repeatedly.
If the detector is in a low power supply fault condition, the
LED flashes 5 times repeatedly.
For models with anti-mask:
If the detector is in anti-mask alarm condition, the LED
flashes 3 times repeatedly.
i
Notice!
The walk test switch does not affect the warm-up flash after power-up or any of the trouble
flash patterns. During the warm-up period, the blue LED flashes continuously until the unit
has stabilized (approximately 2 minutes) and has seen no movement for at least 5 seconds.
Activate LED
1
1
LED
ON
1 2 3
ON
LED
OFF
The ON position enables the LED. If you do not want the LED indication after you finish the
setup and walk tests, put the switch in the OFF position. The OFF position does not prevent
the LED from indicating supervision trouble conditions.
The walk test LED can be controlled remotely by applying power to the W/T terminal matching
the polarity setting of the feature select switch.