6 720 818 731 (2016/07)Tronic 4000 T | Tronic 6000 T
Maintenance/inspection | 13
8.2.1 Function check
Check that all components are functioning correctly.
8.2.2 Magnesium anode
Disconnect the safety switch of the DHW cylinder.
Before starting work, make sure that the DHW cylinder is
disconnected from the power supply.
Completely drain the DHW cylinder ( sec. 6.3).
Remove the screws in the cylinder cover, and remove the
cover.
Disconnect the connecting lead of the temperature limiter.
Remove the fixing screws in the flange [2].
Remove the flange [1].
Check the magnesium anode [3] and replace if necessary.
Fig. 16 Access to the interior and component identification
(example: Tronic 6000 T)
[1] Fixing screws
[2] Flange
[3] Magnesium anode
8.2.3 Regular thermal disinfection
Turn off all hot water taps.
Warn all residents of risk of scalding.
Select the maximum temperature.
Wait until the ON indicator lamp goes out.
Open all hot water taps. Start with the water tap closest to
the DHW cylinder. Let all of the hot water drain for at least
3 minutes from the DHW cylinder.
Close the hot water taps, and set the temperature limiter to
the normal operating temperature.
8.2.4 Extended nonuse (longer than 3 months)
Isolate the DHW cylinder from the power supply.
Completely drain the DHW cylinder.
Fill the DHW cylinder until water drains from all of the hot
water taps.
Connect the DHW cylinder to the power supply.
CAUTION: Damage to the enamel coating!
Never clean the enamel-coated inner walls of
the DHW cylinder using a descaling agent. No
additional products are necessary to protect
the enamel coating.
The DHW cylinder is protected against corrosion
by a magnesium anode inside the cylinder.
WARNING:
Only commission the DHW cylinder with fitted
magnesium anode.
WARNING:
Check the magnesium anode annually and
replace if required. DHW cylinders operated
without this protection are excluded from our
warranty.
DANGER: Risk of scalding!
Hot water can lead to severe scalding during
regular cleaning.
Perform cleaning outside of the normal
operating times.
Replace the water in the DHW cylinder if it has
not been used for a long period (longer than
3months).
2
3
1
6720812247-04.2V