4 | Technical properties and dimension's
appliance. Cleaning and user maintenance
shall not be made by children without
supervision.”
“If the power cable is damaged, it must be
replaced by the manufacturer, its customer
service department or a similarly qualified
person, so that risks are avoided.”
2 Technical properties and dimension's
2.1 Determined use
DHW cylinders are designed for heating and storing potable
water. Please observe national, regional, and local codes,
regulations, guidelines and standards for potable water.
Any other use is considered inappropriate. We take no
responsibility for damage caused through incorrect use.
The service life of the device strongly depends on using water
with appropriate properties.
2.2 Type overview
[ES] Electrical domestic hot water cylinder
[035] Cylinder capacity (liters)
[5] Version
[1200 W] Performance
[BO] Make
[H1, M1] Design
[X] Standard diameter
[C] Capillary temperature controller
[T] Thermometers
[W] Wall-mounted installation
[V] Vertical installation
[R] Reversible installation
[B] Connections to the bottom side
2.3 Description of the DHW cylinder
Enamel-coated steel storage cylinder according to
European standards
High pressure stability
Outer wall jacket: Sheet-metal and/or plastic
Easy operation
CFC-free PU insulation
Magnesium anode
2.4 Corrosion protection
The internal wall of the DHW cylinder is enamel-coated. This
provides fully neutral and water-compatible contact with
possible water. As an additional corrosion protection measure,
a magnesium anode is installed.
2.5 accessories
Fig. 1
[1] Screws (2x)
1)
[2] Rawl plug (2x)
1)
[3] Pressure relief valve (8 bar)
1)
[4] Isolation fitting (2x)
1)
Requirements for
potable water
Units
Water hardness, min. ppm
grain/US gallon
°dH
120
7.2
6.7
pH, min. max. 6.5 – 9.5
Conductivity, min. – max. μS/cm 130 – 1500
Table 2 Requirements for potable water
ES 035 5 1200 W BO H1 XCTWVB
ES 050 5 1600 W
1500 W
BO H1
M1
XCTWR
V
B
ES 080 5 2000 W BO H1
M1
XCTWR
V
B
ES 100 5 2000 W BO H1
M1
XCTWR
V
B
ES 120 5 2000 W BO H1
M1
XCTWR
V
B
ES 150 5 2400 W
2000 W
BO H1
M1
XCTWR
V
B
Table 3