5.4 Water connection
▶ Mark the cold water lines and the DHW lines accordingly to
avoid confusion (Fig. 10).
Fig. 10
[1] Cold water inlet (right)
[2] Hot water outlet (left)
▶ Use suitable accessories for the hydraulic connection of
the DHW cylinder.
Fig. 11 Water connection
[1] Isolation fitting
[2] Hot water outlet
[3] Pressure relief valve
[4] Siphon connection
[5] Gate valve
[6] Pressure reducing valve
[7] Check valve
[8] Connection to the water line
Risk of frost:
▶ Switch off the DHW cylinder.
▶ Drain the DHW cylinder ( sec. 6.3).
Pressure relief valve
Device D
ES050... 180
ES080... 407
ES100... 552
ES120... 702
ES150... 927
Table 7
NOTICE: Corrosion damage to the DHW
cylinder's connections!
▶ Provide the water connections with
insulating dielectric unions. This prevents
current (DC current) from flowing between
the metal hydraulic connections and the
resulting corrosion.
NOTICE: Material damage!
▶ Use a filter at the water inlet if the water has
suspended matter.
Recommendation:
▶ Flush the system beforehand as the water
flow could be reduced by contaminants and,
in case of severe contamination, be stopped
completely.
We recommend the installation of a non-return
valve upstream of the cylinder to prevent faults
resulting from sudden pressure fluctuations in
the water supply (Fig. 11, [7]).
DANGER:
▶ Fit a pressure relief to the cold water
connection on the DHW cylinder (Fig. 11).