EasyManua.ls Logo

Bosch Tronic 6000 T Series - 5.4 Water Connection

Bosch Tronic 6000 T Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 720 818 731 (2016/07)Tronic 4000 T | Tronic 6000 T
Installation | 9
5.4 Water connection
Mark the cold water lines and the DHW lines accordingly to
avoid confusion (Fig. 10).
Fig. 10
[1] Cold water inlet (right)
[2] Hot water outlet (left)
Use suitable accessories for the hydraulic connection of
the DHW cylinder.
Fig. 11 Water connection
[1] Isolation fitting
[2] Hot water outlet
[3] Pressure relief valve
[4] Siphon connection
[5] Gate valve
[6] Pressure reducing valve
[7] Check valve
[8] Connection to the water line
Risk of frost:
Switch off the DHW cylinder.
Drain the DHW cylinder ( sec. 6.3).
Pressure relief valve
Device D
ES050... 180
ES080... 407
ES100... 552
ES120... 702
ES150... 927
Table 7
NOTICE: Corrosion damage to the DHW
cylinder's connections!
Provide the water connections with
insulating dielectric unions. This prevents
current (DC current) from flowing between
the metal hydraulic connections and the
resulting corrosion.
NOTICE: Material damage!
Use a filter at the water inlet if the water has
suspended matter.
Recommendation:
Flush the system beforehand as the water
flow could be reduced by contaminants and,
in case of severe contamination, be stopped
completely.
6720812247-02.1V
2
1
We recommend the installation of a non-return
valve upstream of the cylinder to prevent faults
resulting from sudden pressure fluctuations in
the water supply (Fig. 11, [7]).
DANGER:
Fit a pressure relief to the cold water
connection on the DHW cylinder (Fig. 11).
6720818520-06.1V
1
5678
3 421

Related product manuals