MX130 & MX230
6.2.Technical datasheet
General
Size of the unit (Height x Width x Depth)
345 x 235 x 152
Dry weight MX130
MX23
0
3.8 kg
4.3 kg
Connection details
Cold water inlet
15mm Compression
System outlet
15mm Compression
Drain
21.5 Waste pipe
Maximum inlet pressure
10 bar
Maximum delivery pressure
3 bar
Maximum design pressure
PN6
Nominal flow rate (1bar)
0.5 l/min
Electrical details
Supply voltage
230 Volt
Frequency
50 Hz
Full load current
0.3A
Fuse rating
5A (or 6A MCB)
Maximum load BMS relays
5A @ 240VAC (non-inductive)
Protection class
IP2X
Environmental data
Power consumption (Standby)
2 W
Power consumption (Filling)
28 W
Operation conditions
Maximum temperature at inlet:
45°C
Maximum temperature at outlet:
85°C
Ambient temperature range:
5°C / 45°C
Storage conditions
Temperature
5°C / 45°C
Humidity
60-70% relative humidity, non-
condensing.