Always wear ANSI Z87.1 compliant eye protection against flying particles.
Do not use oxygen, combustible gases, or bottled gases; avoid pressures over 200 PSI.
Never place body parts in discharge area, point at anyone, or engage in horseplay.
Handle tool with care, never engage in horseplay, keep others at a distance.
Do not hold trigger pulled except during fastening to prevent accidental cycling.
Keep hands and body away from discharge to avoid injury from recoil or second fastener.
Never use nailer near flammable substances or vapors due to explosion risk.
Use only clean, regulated compressed air; never oxygen or combustible gases.
Reiterates eye protection, no body parts in discharge, no pointing, no horseplay.
Load nails through slot, pull back pusher, ensure pusher is behind last nail.
Tool fires when contact trip touches work and trigger is pulled. Risk of double fire.
Tool fires when contact trip is on work, then trigger is pulled. Prevents double fire.
Lock trigger, rotate mode switch to select Contact (down) or Sequential (up).
Use tool only for its intended purpose, never as a hammer or towards people.
Carry by handle, never alter tool without approval, be aware of misuse risks.
Jams can be caused by hitting metal plates, screws, or other hard objects.
Disconnect air, release pusher, open nose door, remove fastener, close door, reset pusher.
Addresses leaks in trigger valve housing, stem, frame/nose, and frame/cap.
Covers failure to cycle and lack of power/slow cycling causes and corrections.
Addresses skipping fasteners and fasteners jamming in the tool.