EasyManuals Logo

Botex DR-512 User Manual

Botex DR-512
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
User Manual DR-512
For external storage, press CARD key, the relevant LED will light up, that means you
have entered the CF card operation(CF card should be firstly formatted before use).
The UP / DOWN keys can be used to choose sequences, and the PLAY / PAUSE /
STOP keys can be used to control the running of sequences. When under the state
of “STOP”, press the CARD key for a second time to return to the internal operation.
Should the selected sequence not exist, the PLAY function will not be effective.
NEXT, ENTER and RECORD functions will disabled when under the MANUAL mode.
6.2 AUTOSTART mode
Under AUTOSTART mode, the foregoing recorded sequences can be rerun
automatically (To CF card , the sequences of STARTUP and SHUTDOWN will not be
trigged). During sequence running, press STOP key to activate the SHUTDOWN
sequence, when it stops running, all sequences will be stopped.
AUTOSTART can be executed once. After the STARTUP sequence finished, the
selected sequences will run automatically, and relevant operation can be done
manually. Subsequently press the STOP key, the SHUTDOWN sequence will run
within a cycle.
STARTUP and SHUTDOWN sequences can not be operated manually under this
mode, they can only automatically run after respectively pressing the PLAY and
STOP keys.
AUTOSTART can be rerun the next time when the unit restarts.
6.3 DMX MON mode
Under this mode, DMX signals can be monitored. In the case that the DMX signals
are disabled, this unit can initiate a prepared system to enable the pre-selected
sequences.
When there is an effective signal input, the DMX indicator will light up, and the signal
(DMX Thru) will be send out through this unit. If the signal is missing, STARTUP and
the selected sequences will be triggered automatically. Press STOP key to stop the
running sequences. After the SHUTDOWN sequence run over, all the operation will
be finished.
This unit can only check the effective DMX signals. If there is no data input, the
pre-selected sequences will be output normally.
STARTUP and SHUTDOWN sequences can not be operated manually under this
mode. And the AUTOSTART mode may be available for reference to the operation
upon MANUAL mode.
7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Botex DR-512 and is the answer not in the manual?

Botex DR-512 Specifications

Power IconPower
power requirementDC 9-12V, 500mA min
fuseF 500mA 250V 5×20mm
binary coded switch input0~5V (no external voltage) /1mA
Display IconDisplay
lcd screen2×16 characters
Weight and Dimensions IconWeight and Dimensions
dimensions482×120×44mm
weight1.6 kg