User Manual DR-512
• Once received effective DMX signals, the running sequences will be stopped
automatically. Function upon PLAY, PAUSE and STOP keys will disabled.
• Should the DMX signals be disabled, operation could be done manually.
6.4 DMX TRIGGER mode
• Under this mode, the first four DMX channels(Ch1~Ch4) can be used to respectively
control
I01~I04 sequences. I01~I04 sequences will run effectively when the DMX
level of each relative channel ≥20%. And on the other hand, these sequences will
stop running while the relevant level <20%.
• Only if the DMX input is effective (DMX indicator “on”), should the DMX TRIGGER be
well done.
• Sequences (including STARTUP and SHUTDOWN) can be operated manually under
DMX TRIGGER mode.
6.5 PROGRAM mode
Under this mode, any one of the sequences can be recorded, and the sequence
name can also be amended.
6.5.1 Recording operation
• Select the sequence to be recorded (including the internal sequences and the
external sequences). And the CF card must be formatted before use.
• Check the states of the DMX indicator. When the relevant LED is “on”, that means
the DMX input is effective, while LED “off” means no signal input.
• Give the RECORD key a press, the sequence control will be paused, and the
relevant data will be erased.
• Press PAUSE or PLAY key for recording. And press STOP key to stop the operation
at any moment you want.
• Warning : when during operating, please do not turn off the unit , otherwise the
relevant recorded data will be missing.
6.5.2 Changing the sequence name
• In PRG Mode, When the unit is in the state of “STOP”, press the “Enter” key to enter
the further menu, and there will be an underline appears on the top left corner of the
LCD-display.
• Press NEXT key to move to the selected character, and use UP/DOWN keys to
change the relevant characters. Press ENTER key to confirm your operation.
• The Smpte time will not be changed while amending the sequence name.