6. Installation
6.1 Surrounding conditions
6.1.1 Regulations
Applicable regulations for room ventilation and size, odour
and noise emissions, accident prevention etc. must be met.
The control box contains contacts to control the room air ventilation
(see page 28).
Noise level at a distance of 1 meter (39.3 inch) P 240 /P 300
from the machine and 1.60 m (63 inch) above P 300 USA /P 350 USA
ground (without sound insulation): 64 dB (A)
_________________________________________________________________________
If there is an increase of the airbome sound e.g. by resonance because of space situation
the condition and the distances of the walls and the ceiling etc. it is necessary to take
additional measures of sound insulation.
6.1.2 Temperature
Machine should not be exposed to direct sunlight.
Adequate air supply is to be ensured due to heat exchange
(heat build-up!) Room temperature should not drop below
1 °C (34 °F) owing to the risk of water freezing in the system, and
not exceed 40 °C (104 °F) in continuous operation owing to increased
solvent consumption.
P 240 P 300
P 300 USA P 350 USA
Heat radiation: 9300 kJ 11500 kJ
_________________________________________________________________________
6.1.3 Structural surroundings
Partitions, screens, intermediate ceilings and similar near
the machine are to be fitted in such a way that they do not
hinder operation and are easily and quickly removed for
maintenance and repair.
NOTE!
Do not operate appliances with open flames, e.g. gas-fired
flatwork ironers, tumblers, in the same room, because they
can be damaged by noxious, corrosive gases in the event of
solvent decomposition.
Please ensure that no air from the machine can escape into
a possibly existing heating plant room.
!