21
7. Connection
Crossline
703868-12-A
We reserve the right to change measurements!
Pos. Medium NW Zoll - X - - X - - Y - - Y -
mm inch mm inch mm inch
________________________________________________________________________
1 Steam still 15 1/2 910 35.8 1440 56.7
2 Condensate still 15 1/2 1640 64.6 190 7.5
3 Condensate heater 15 1/2 785 30.9 1400 55.1
4 Steam heater 15 1/2 1650 65 965 38
5 Cooling water inlet without tank cooling 15 1/2 950 37.4 1220 48
6 Cooling water inlet with tank cooling 15 1/2 420 16.5 90 3.5
7 Cooling water inlet still electr.
with water addition 15 1/2 950 37.4 440 17.3
8 Cooling water outlet 20 3/4 955 37.6 1400 55.1
9 Compressed air 8 1/4 140 5.5 1400 55.1
10 Electr. connection 890 35 1480 58.3
11 Venting water separator 22 - 1160 45.7 1420 55.9
12 Rake out system - pump out 20 3/4 1580 62.2 1020 40.2