9. Technical data
P 350 USA with /without Slimsorba
Heating steam electr.
CONSUMPTION DATA:
CONSUMPTION PER LOAD*
El. energy total without /with Slimsorba kWh 2.4/2.6 8.8/10.6
El. energy drying without /with Slimsorba kWh 2.2/2.3 3.5/3.6
El. energy still kWh - 5.3
Saturated steam drying without /with Slimsorba lb 6.2/6.6 -
Saturated steam still lb 14.3 -
Cooling water drying without /with Slimsorba US gal 14.5/18.5 15.9/18.5
Cooling water still US gal 22.5 25.1
Compressed air (6 bar) US gal 1.6 1.6
OTHER DATA:
Still throughput (DIN 11916) max. US gal /h 31.7 19.8
Filter throughput US gal /h 1057 1057
Filter surface ECO-filter sq.ft.
25.8 25.8
Weight without solvent Slimline /Crossline lb 2381 /2426 2381 /2426
Weight with solvent Slimline /Crossline lb 3241 /3286 3241 /3286
Carbon-filling Slimsorba lb 22.1 22.1
Floor surface Slimline /Crossline sq.ft
24.7/26.9 24.7/26.9
Used floor surface*** Slimline /Crossline sq.ft
15.2 /15.2 15.2 /15.2
Centrifugal cage force N 6000 6000
Floor load (stat. and dyn.) max.
. Slimline /Crossline N/m
2
14500/14600 14500 /14600
Noise level dB(A) 64 64
HEAT BALANCE:
Heat eliminated by cooling water****:
with /without Slimsorba kJ/h 32000 /31000 33500 /32500
Heat radiation to the ambient*:
with /without Slimsorba kJ/h 11700 /11500 11700 /11500
* Values apply to a standard 2-bath-cycle, 1. bath to distillation at cooling water inlet temperature + 12 °C (53.6 °F).
Drum outlet temperature 50 °C (122 °F), condensation pressure 22 bar (319 psi), drying 18 minutes, reduction 6 minutes,
steam supply 4 - 5 bar (58 - 72.5 psi) saturated steam, ambient temperature + 1 to + 40 °C (+ 34 to 104 °F),
with Slimsorba 3 min. reduction, 6 min. adsorption.
*** used part of floor surface for force transmission see point 6.3.1
**** refers to water without any additive
Subject to technical changes!