EasyManua.ls Logo

BÖWE P26 - Page 19

Default Icon
89 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
P21/P26/P30
4. Technical Specifications 4.
P21
Heating
Steam
Electric
Consumption for drying:
Drying time inc. reduction min. 15 15
Elec. energy drying
Without Slimsorba
With Slimsorba
kWh
kWh
2.4
2.6
4.0
4.2
Saturated steam drying
Without Slimsorba
With Slimsorba
kg (lb)
kg (lb)
4.0 (8.8)
4.0 (8.8)
-
-
Cooling water drying (12 °C/53.6 °F)
Without Slimsorba
With Slimsorba
l (US gal)
l (US gal)
85 (22.4)
75 (19.8)
85 (22.4)
75 (19.8)
Consumption for distillation(1x at low level):
Elec. Energy, distillation kWh - 8.0
Saturated steam, distillation kg (lb) 12.0 (26.5) -
Cooling water for dist. (12 °C/53.6 °F) l 160 (42.2) 160 (42.2)
Consumption per cycle: *
Total elec. energy
Without Slimsorba
With Slimsorba
kWh
kWh
2.8
3.0
12.0
12.2
Total saturated steam
Without Slimsorba
With Slimsorba
kg (lb)
kg (lb)
16.0 (35.3)
16.0 (35.3)
-
-
Total cooling water (12 °C/53.6 °F)
Without Slimsorba
With Slimsorba
l (US gal)
l (US gal)
245/235
(64.7/62.0)
245/235
(64.7/62.0)
Compressed air (6 bar/87 psi) l (US gal) 6 (1.6) (1.6)

Table of Contents